The PDUMH15HVAT 2–2.4kW SinglePhase 200–240V Local Metered Automatic Transfer Switch / ATS PDU enables redundant power for network devices with nonredundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIAstandard 19inch racks and features 10 C13 outlets. Dual 3.6meter input cords with IEC320 C14 plugs connect to separate primary and secondary singlephase power sources in a nominal voltage range from 200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVAT constantly evaluates the power quality of both input sources. Dynamic solidstate (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Builtin slot supports the optional WEBCARDLX (sold separate), which turn the PDUMH15HVAT into a switched PDU by allowing remote access to the PDU for power monitoring, configuration, outlet control and notifications via web browser, SSH, telnet or SNMP. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs. Primary and Secondary Inputs for Power Redundancy Enables redundant power for network devices with nonredundant power supply configurations Dual 3.6 m input cords with IEC320 C14 plugs connect to separate primary and secondary singlephase power sources 10 C13 outlets Automatic Transfer Switching Dynamic solidstate (TRIAC) automatic transfer switching Switches to secondary power source if primary source fails or becomes unstable 2–5 ms transfer time ensures uninterrupted operation of connected equipment Builtin processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source Digital Load Meter Easytoread ammeter displays total current used by connected equipment LED Indicators Individual LEDs display outlet on/off status and input power status on primary and secondary inputs Advanced Network Monitoring Options Builtin card slot accommodates SNMPWEBCARD and WEBCARDLX accessories (sold separately) Optional cards create a switched PDU by allowing remote access for power monitoring, configuration, outlet control and notification via web browser, SSH, telnet or SNMP Mounts Horizontally in 1U of Rack Space Compatible with EIAstandard 19 in. racks TAACompliant Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Brand
- Tripp Lite