The ATEN NRGence™ PE5221T eco PDUs are thin form factor intelligent PDUs that contain 21 AC outlets available in IEC or NEMA socket configurations. The lightweight thin form factor eco PDUs have a smaller width and input region than ATEN’s standard and low profile PDUs. The thin form factor series have a 56 mm width that fits tight into server racks providing more space for cooling and maintenance. The smaller design leaves 8% more space in the rack to increase air flow and cool IT equipment more effectively. It also means faster maintenance with easier access to equipment normally installed behind the PDU.
NRGence™ eco PDUs offer real-time power measurement and threshold alerts – allowing you to monitor the PDU’s power status, bank status and circuit breakers, either at the PDU or from any location via a TCP/IP connection.
With the combination of ATEN eco PDUs and eco DC Energy Management Web GUI, a data center is equipped with real-time monitoring, measurement and analysis of energy consumption – with reports of power usage and PUE to meet the ISO 50001 requirements. These indexes will automatically generate customized reports about your data center’s energy use and include energy saving suggestions. The suggestions allow you to optimize energy usage and save money without harming your IT equipment’s reliability. eco DC Energy Management Web GUI provides easy multi-PDU management with an intuitive user-friendly interface that allows you to configure PDUs and monitor the power status of equipment connected to them.
NRGence™ eco PDUs offer real-time power measurement and threshold alerts – allowing you to monitor the PDU’s power status, bank status and circuit breakers, either at the PDU or from any location via a TCP/IP connection.
With the combination of ATEN eco PDUs and eco DC Energy Management Web GUI, a data center is equipped with real-time monitoring, measurement and analysis of energy consumption – with reports of power usage and PUE to meet the ISO 50001 requirements. These indexes will automatically generate customized reports about your data center’s energy use and include energy saving suggestions. The suggestions allow you to optimize energy usage and save money without harming your IT equipment’s reliability. eco DC Energy Management Web GUI provides easy multi-PDU management with an intuitive user-friendly interface that allows you to configure PDUs and monitor the power status of equipment connected to them.
Supported Network Protocols
- TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, and SNMP V1,V2&V3
Password Protection
- Yes
Block 1 Output Current
- 16 A
Nominal Output Voltage
- 100 - 240 V
AC Outlets Quantity
- 21 AC outlet(s)
Power Plug
- C20 coupler
PDU Types
- Metered, Monitored
Nominal Input Voltage
- 100 - 240 V
Monitoring
- Current, Power, Voltage
Maximum Current
- 16 A
Load Capacity
- 3680 VA
AC Outlet Types
- C13 coupler, C19 coupler
Rack Capacity
- 0U
Sustainability Compliance
- Yes
AC Input Frequency
- 50 - 60 Hz
Compliance Certificates
- CE, Federal Communications Commission (FCC), Low Voltage Directive (LVD), RoHS
Ethernet LAN (RJ-45) Ports
- 2
Storage temperature (T-T)
- -20 - 60 °C
Cables included
- AC
Operating temperature (T-T)
- 0 - 50 °C
Security algorithms
- 128-bit SSL
Cable length
- 3 m
Weight
- 2.34 kg
Depth
- 902 mm
Width
- 56 mm
Height
- 48 mm
Product colour
- Black
Brand
- ATEN

UK Address:
466 Malton Avenue,
Slough,
SL1 4QU,
United Kingdom
Website (UK): www.aten.com/eu/en
Email (UK): support@aten.co.uk
EU Address:
Mijnwerkerslaan 34,
3550 Heusden-Zolder,
Belgium
Website (EU): www.aten.com/gb/en
Email (EU): support@aten.be
This product complies with the General Product Safety Regulation (GPSR) and meets all relevant EU safety standards.
For detailed compliance documents, please review the provided link above.
If you have any questions or require further assistance, you can:
- Contact the manufacturer directly at the listed addresses or support emails.
- Email Northamber Product Safety at productsafety@northamber.com.